Jun 01, 2025 Leave a message

What Precautions Should Be Taken During Daily Maintenance Of The Enhanced Optical Cable Traction Machine?

Daily maintenance of the enhanced optical cable tractor is the basis for ensuring efficient operation of the equipment and extending its life. The following are the key points to pay attention to during daily/shift operations, which are explained in combination with safety regulations and details:
1. Before starting: Comprehensive inspection of the "five elements"
1. Mechanical cleaning and removal of foreign objects
Key parts:
Track/belt groove: Use a screwdriver or special hook to remove embedded stones and optical cable debris (pay special attention to hard objects between the rubber teeth) to avoid scratching the optical cable or aggravating track wear during operation.
Guide wheel group: Wipe the wheel surface oil and check whether the wheel axle is stuck (manual rotation should be smooth without abnormal noise).
Tool recommendation: Compressed air gun (air pressure ≤ 0.5MPa) to blow away dust in the gaps of the fuselage, and wipe the operation panel with a damp cloth (solvents are prohibited to prevent key failure).
2. Fastener and drive system inspection
Bolt/nut tightening:
Use a wrench to check the track tensioning bolts (adjust symmetrically on both sides), engine bracket screws, and guide wheel fixing bolts to ensure that they are not loose (reference torque: M10 bolts 25-30N・m, M12 bolts 40-45N・m).
The transmission chain (if any) needs to be observed for sag (sag ≤20mm), and the chain oil (such as WD-40) should be sprayed for lubrication to avoid dry grinding and abnormal noise.
3. Oil and power system
Engine inspection:
Check the oil dipstick, the oil level must be between the upper and lower limit scales (if insufficient, add the same brand of oil to avoid mixing); check the fuel tank for gasoline models, and confirm to use -10# gasoline in winter (to prevent freezing).
Test the battery voltage (≥12V) for electric start models. If it is lower than 10.5V, charge or replace the battery.
Hydraulic system (if any): Observe the oil tank level gauge, the oil level should be above the minimum scale line, and there should be no oil leakage at the oil pipe joint (check by wiping with a paper towel).
4. Electrical and safety device test
Sensor function:
Pull the optical cable manually to trigger the tension sensor, confirm that the equipment can stop and alarm within 3 seconds, and the buzzer and warning light are working properly.
Test the emergency stop switch (the red button on the fuselage and the "emergency brake" button on the remote control), and the crawler should lock immediately after pressing it.
Remote control inspection: Replace low-power batteries (alkaline batteries are recommended), and test the response sensitivity of each button (such as forward/backward/acceleration/deceleration functions).
5. Environment and installation safety
Confirm that the working ground is flat (slope ≤5°). If it is a soft ground, a steel plate (thickness ≥10mm) must be laid to prevent the equipment from sinking.
When overhead traction, check that the guide pulley is firmly installed (load bearing ≥2 times the weight of the optical cable) and that there are no broken strands in the wire rope (the number of broken wires ≤10% of the total number of wires).
2. During operation: Dynamic monitoring of "three key points"
1. Instrument data observation
Tension fluctuation: The normal range should be ≤±10% of the set threshold. If it is continuously higher than the threshold (such as more than 3000N), it is necessary to immediately decelerate to 10 meters/minute to check whether it is caused by the sharp corner of the pipeline (radius of curvature <20 meters) or the optical cable knot.
Engine temperature: The water temperature gauge of the gasoline engine should be <95℃. If an alarm is triggered, the engine must be stopped and cooled at idle speed (it is forbidden to open the cover and add water directly to prevent boiling).
Meter meter accuracy: Compare the actual tape measurement value every 500 meters of construction. When the error is greater than 1.5%, stop and calibrate (through the "coefficient adjustment" function of the operation panel).
2. Abnormal sound and vibration identification
Abnormal sound judgment:
"Clicking" sound: It may be that the track is clamped with stones or the gears are not meshing properly. It is necessary to stop the machine to clean/check the transmission box.
"Buzzing" high-frequency vibration: The guide wheel bearing is lacking oil or eccentric, and grease (lithium-based grease, needle penetration 265-295) should be added immediately.
Prohibited behavior: Do not touch the track, gears and other rotating parts with your hands during operation. If you need to adjust the position of the optical cable, you must first stop and lock the track.
3. Environmental adaptability operation
High temperature weather (>35℃): Stop the machine for 10 minutes every 2 hours of operation to dissipate heat and avoid engine overload; check that the water tank fan is operating normally.
Humid environment: Use a multimeter to detect the grounding resistance of the equipment (≤4Ω) before starting work every day to prevent leakage; apply vaseline to the electrical interface to prevent moisture.
3. After shutdown: "Four steps" of final maintenance
1. Cleaning and rust prevention
Body cleaning: Use a shovel to remove the dry mud on the surface of the track, spray a neutral detergent (such as car wash liquid) and rinse with clean water (avoid the motor and control box), wipe dry and spray rust inhibitor (such as CRC rust prevention oil) on metal parts (such as frame and bolts).
Optical cable debris cleaning: Focus on cleaning the gap between the guide wheel and the track to avoid debris accumulation and cause jamming when starting the next day.
2. Lubrication and component reset
Active joint lubrication: Drip lubricating oil (such as 30# mechanical oil) into the active parts such as the guide wheel shaft and track tensioning screw, and rotate the parts 2-3 times to fully lubricate.
Track loosening: When the machine is shut down for a long time, rotate the track tensioning bolt counterclockwise 2-3 times to release the internal stress (re-adjust to the standard tension before starting the machine the next day).
3. Energy and safety management
Fuel and battery:
If the gasoline engine is stopped for more than 24 hours, it is recommended to drain the fuel tank (to prevent the fuel from deteriorating and clogging the injector); the diesel engine needs to turn off the fuel tank switch.
Disconnect the negative connection line of the rechargeable battery to avoid long-term self-discharge damage (charge once a week and keep the power ≥50%).
Safety lock: Enable the mechanical locking device of the equipment (such as the track brake pin), and place the remote control in the tool box to prevent misoperation.
4. Fill in maintenance records
Register the "Daily Maintenance Log", including:
The running time, traction length, and maximum tension value of the day;
Abnormalities found (such as loose bolts, sensor false alarms) and treatment results;
Models and quantities of replaced parts (such as batteries and tracks).
4. Special seasonal precautions
1. Winter (temperature < 0℃)
Preheat the engine before starting: For electric start models, short press the start button 2-3 times (without ignition) to heat with the preheat plug; for manual start, slowly pull the start rope 5-10 times for pre-lubrication.
Grease replacement: Change the lithium-based grease used daily to a low-temperature type (applicable at -30℃) to prevent grease solidification from affecting transmission.
2. Summer (temperature > 30℃)
Increase heat dissipation inspection: Check the tightness of the engine cooling fan belt every day (press the middle of the belt with your thumb, deflection ≤10mm), and clean the dust on the radiator fins of the water tank (blow from the inside to the outside with compressed air).
Avoid exposure to the sun: The equipment is parked under a sunshade, and the operation panel is covered with a sunscreen cloth to prevent aging and cracking of plastic parts.
5. Taboos and risk avoidance
It is forbidden to use diesel to clean the track: diesel will accelerate rubber aging, and a special rubber cleaner (such as 3M 08946) is required.
Avoid overload testing: It is strictly forbidden to pull the equipment with excessive tension (such as exceeding the nominal tension of the optical cable by 100%) to test the equipment limit, which may cause the frame to deform or the transmission gear to break.
Outdoor charging is prohibited on rainy days: the charging interface must be kept dry to prevent short circuit and fire (except for waterproof chargers).
By strictly implementing daily maintenance, more than 90% of potential faults (such as early bolt loosening and track wear) can be discovered in time, reducing the risk of downtime to ≤1 time per month. If complex problems are found (such as oil leakage in the hydraulic system and abnormal PLC program), contact the manufacturer's technicians immediately, and do not disassemble the core components by yourself to avoid further losses.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry